Completeness
Module includes: -Productive manifold with stop valves; -test manifold with stop valves; -drain manifold with stop valves; -instruments. Modules-shelters are equipped with systems of electric or water heating, lighting, ventilation, fire alarm and gas-content detectors.
Inlet Manifold Module can be placed within a shelter or at open site on a frame and manufac-tured in various completeness depending on Customer requirements. Premise of Inlet manifold module is executed from modules with dimensions of 3000x6000x2950 mm, 3000x9000x2950 mm, 3000x12000x2950 mm which can be joined and completed in any option as per Customer and Designer requirements.
Manufacture of Inlet manifold module conform to OCT 26.260.18-2004 "Technological modules for gas and oil industry. General technical requirements"
Designation
Exemplary symbolic notation when ordering Inlet manifold in module-shelter with the conventional pressure 4,0 MPa, conventional diameter of the production manifold 200mm, number of inlet pipelines 8, conventional diameter 100mm, and climatic execution per GOST 15150 for moderate and cold climate: BGI-4,0-200-8-YXL1
Exemplary symbolic notation when ordering Inlet manifold on open frame with the conventional pressure 4,0 MPa, conventional diameter of the production manifold 200mm, number of inlet pipelines 8, conventional diameter 100mm, and climatic execution per GOST 15150 for moder-ate and cold climate: BGII-4,0-200-8-YXL1.
Technical Data
|
Operational Medium |
Oil wells products (oil, gas, formation water) |
|
Operational Pressure, MPa |
1,6; 2,5; 4,0; 6,3 |
|
Number of operational lines |
As required by customer |
|
Number of research lines |
As required by customer |
|
Inside module temperature, C, min |
+5 |
|
Fire and Explosiveness Risk Category according to NPB 105-95 |
A |
|
Ambient temperature, оC |
-50…+50 |
|
Module Dimensions, mm |
3000x6000x2950
3000x9000x2950 |
|