Completeness
Modular tubular heater with intermediate heat-carrier of NG-1, NG-2 types; com-pleted with heating and air supply system, preheater, gas-regulating equipment with burner, power devices panel, automatics panel, shelter-module with dimensions of 3000x6000x2950mm.
Modular tubular heaters on gas fuel of NG-1, NG-2 types conform to OCT 26.260.18-2004 "Technological modules for gas and oil industry. General tech-nical requirements"
Technical Data
|
Parameters |
NG-1 |
NG-2 |
|
Operational medium |
Oil emulsion
(water content up to 30%) |
|
Thermal power MW |
0,29 |
1,55 |
|
Output t/day |
100…500 |
1000…1500 |
|
Operating pressure in product coil,M Pa not more than |
6,3 |
6,3 |
|
Product inlet temperature îC, not less than |
5 |
5 |
|
Product heating temperature, not more than îC |
52 |
52 |
|
intermediate heating-carrier temperature, not more than îC |
52 |
52 |
|
Fuel |
Natural gas, Accompanying oil gas |
|
Heater inlet pressure M Pa |
0,6…6,0 |
0,6…6,0 |
|
Gas pressure (nominal) upstream the burner, MPa |
0,75 |
0,75 |
|
Fuel gas consumption m3/hour, not more than |
35 |
280 |
|
Consumed electric power kW, not more than |
1,0 |
50,0 |
|
Efficiency %, not less than, |
82 |
82 |
|
Average service life, years, not less than |
10 |
10 |
|
Ambient temperature, îC, |
-50…+50 |
|
Weight of the heater, idle, kg, not more than |
3600 |
19000 |
|
Module category for gas burner per ÍÏÁ 105-03 |
à |
à |
|